Analytical Electronics Services Pvt Ltd

Budgetary Source of Test & Measuring Equipment

Authorized Distributor

AES, India - Authorized Distributor of Pico Technology    AES, India - Authorized Distributor of DranetzBMI    AES, India - Authorized Distributor of Pintech
Buy Sell Rent Repair

Pintech HVP-40 (40KV.60Hz) high voltage probe for DMM

Pintech HVP-40



Input Resistance 1000MO; Attenuation Ratio 1000 : 1 Max. Operation Voltage DC 0~ ± 40KV Accuracy DC : ± 1% to 20 KV , ± 2% to 40 KV AC:- 5% to - 10% at 50 ~ 60Hz

Pintech HVP-40 Specification

Input Resistance 1000MO;
Attenuation Ratio 1000:1
Max. Operation Voltage DC 0~ ± 40KV
AC 1~ 28KV(50/60Hz)
Safety APPL EN61010 , UL3111-1 , TUV-GS
IEC1010 CAT? Pollution 2
Polarity Positive/negative are measurable
txt" - DC:± 1% to 20 KV , ± 2% to 40 KV
AC:- 5% to - 10% at 50 ~ 60Hz
Temperature Coefficient ? 200ppm /?
Maximum Loading Current ? 40µA ( at 40KV DC )
Maximum Loading Power ? 1.6 watt
Operating Temperature 0? ~ + 50?
Designated link 10MO input impedance DMM
Meter output instructions X 1000, 1V?1000V
10V?10KV
Remark The meter which is selected to use should has 10Mohm input impedance besides the accuracy should between ±0.5%, otherwise it will seriously affect attenuation ratio.

Feel free to contact us for any queries you may have.